ACCIDENT ANALYSIS OF LOW PRESSURE GAS DISTRIBUTION SYSTEMS

Alexander Shkarovskiy, Maciej Kotuła

Abstract


In terms of safety, gas supply represents a highly important area of science and engineering. On the one hand, gas is a very convenient primary energy source for consumers. On the other hand, gas can be extremely dangerous for life and health of people, if strict requirements to design, construction and operation of gas supply systems are not complied with. The article reviews an accident that occurred in a small Polish city in 2010. We analyzed data from the Prosecutor’s Office and relevant publications and questioned workers of the gas supply company. The article describes how an unlucky train of events resulted in a tragedy. The main circumstances were an unacceptable change in the gas distribution plant equipment and violation of operating rules, which resulted in an unauthorized pressure increase in a district network and internal systems designed for low pressure. We analyzed follow-up technical and administrative measures taken regarding the Polish gas supply system and compared some peculiarities of Polish and Russian gas technologies. The main purpose of the analysis is to prevent such accidents in future.

Keywords


Gas supply, safety, gas distribution plant, equipment, operation, pressure increase.

Full Text:

PDF

References


Ansari, N., Ayatollahi, S., Riazi, M. (2017). Underground natural gas storage in a low quality gas reservoir - Produced gas quality control by rate optimization. In: Proceedings of 79th EAGE Conference and Exhibition 2017: Energy, Technology, Sustainability - Time to Open a New Chapter.

Federal Agency on Technical Regulation and Metrology (2015). GOST 5542-2014. Natural fuel gases for commercial and domestic use. Specifications. Moscow: Standartinform.

Fu, X., Li, G., Zhang, X., Qiao, Z. (2018). Failure probability estimation of the gas supply using a data-driven model in an integrated energy system. Applied Energy, 232, pp. 704–714. DOI: 10.1016/j.apenergy.2018.09.097.

Interia Fakty (2018). USA: series of gas explosions. Several dozen explosions. Available at: https://fakty.interia.pl/swiat/news-usa-seria-wybuchow-gazu-kilkadziesiat-eksplozji,nId,2631139. (accessed on: 12.09.2018)

Kim, J.-H., Doh, D.-H., Choi, B.C. (2018). Evaluation of the ventilation safety requirements for the fuel gas supply system room of a gas-fueled vessel: Simulated leaks of methane and propane. Journal of Mechanical Science and Technology, 32 (11), pp. 5521–5532. DOI: 10.1007/s12206-018-1050-7.

Prokuratura Okrégowa (2013). The indictment against the gas distribution network master in the case of gas explosion in Zielona Góra neighbourhood. Available at: http://www.zielona-gora.po.gov.pl/index.php?id=3&ida=9326. (accessed on: 18.10.2018)

Super Express (2010). Zielona Góra: Gas stove explosions in residential buildings. Available at: http://www.se.pl/wiadomosci/polska/kuchenki-wybuchay-ludziom-w-domach_162460.html. (accessed on: 12.09.2018)

Szkarowski, A., Janta-Lipińska, S., Kolienko, A. (2013). Gas quality control as a tool of energy saving. Gas, Water and Sanitary Engineering, 4, pp. 146–150.

Szkarowski, A. (2014). Gas combustion. Theory, practice, ecology. (Warsaw: WNT Publishing House).

Tymchik, G.S. et al., (2018). Quality control system of well-bonded coupling fitting onto high pressure gas-main pipelines. In: Proceedings of SPIE - The International Society for Optical Engineering, 108085A. DOI: 10.1117/12.2501594.

Vasista, T.G., Alsudairi, M.A.T. (2018). Managing through computer aided quality control in oil & natural gas industry project sites. Journal of Advanced Research in Dynamical and Control Systems, 10 (4), pp. 896–905.

Wang, Y., Yang, S. (2018). Proposal and thermodynamic analysis of a combined open-cycle absorption heat pump and thermal desalination system driven by high-humidity exhaust gas. Desalination, 448, pp. 93–102. DOI: 10.1016/j.desal.2018.10.003.