STUDY ON WATER LEAKAGE DETECTION AND TREATMENT IN METRO STATION STRUCTURES
Abstract
Keywords
Full Text:
PDFReferences
Asakura, T. and Kojima, Y. (2003). Tunnel maintenance in Japan. Tunnelling and Underground Space Technology, Vol. 18, Issues 2–3, pp. 161–169. DOI: 10.1016/S0886-7798(03)00024-5.
Cheng, X., Hu, X., Tan, K., Wang, L., and Yang, L. (2021). Automatic detection of shield tunnel leakages based on terrestrial mobile LiDAR intensity images using deep learning. IEEE Access, Vol. 9, pp. 55300–55310. DOI: 10.1109/ACCESS.2021.3070813.
Clark, M. R., McCann, D. M., and Forde, M. C. (2003). Application of infrared thermography to the non-destructive testing of concrete and masonry bridges. NDT & E International, Vol. 36, Issue 4, pp. 265–275. DOI: 10.1016/S0963-8695(02)00060-9.
Feng, D.-S., Chen, C.-S., and Yu, K. (2011). Signal enhancement and complex signal analysis of GPR Based on Hilbert-Huang transform. In: Wan, X. (ed.). Electrical Power Systems and Computers, Lecture Notes in Electrical Engineering, Vol. 99, pp. 375–384. DOI: 10.1007/978-3-642-21747-0_46.
Gong, X.-N. and Guo, P.-P. (2021). Prevention and mitigation methods for water leakage in tunnels and underground structures. China Journal of Highway and Transport, Vol. 34, Issue 7, pp. 1-30. DOI: 10.19721/j.cnki.1001-7372.2021.07.001.
Han, S., Cho, H., Kim, S., Jung, J., and Heo, J. (2012). Automated and efficient method for extraction of tunnel cross sections using terrestrial laser scanned data. Journal of Computing in Civil Engineering, Vol. 27, Issue 3, pp. 274–281. DOI: 10.1061/(ASCE)CP.1943-5487.0000211.
Jiang, Y., Wu, J., Ma, Y., and Huang, B. (2020). Research and application of detection technology of tunnel lining concrete strength based on impact elastic wave. Railway Engineering, Vol. 60, Issue 6, pp. 1–5, 11. DOI: 10.3969/j.issn.1003-1995.2020.06.01.
Kashani, A. G., Olsen, M. J., Parrish, C. E., and Wilson, N. (2015). A review of LIDAR radiometric processing: From ad hoc intensity correction to rigorous radiometric calibration. Sensors, Vol. 15, Issue 11, pp. 28099–28128. DOI: 10.3390/s151128099.
Lam, S. Y. W. (2006). Application of terrestrial laser scanning methodology in geometric tolerances analysis of tunnel structures. Tunnelling and Underground Space Technology, Vol. 21, Issues 3–4, p. 410. DOI: 10.1016/j.tust.2005.12.057.
Liu, B., Li, S.-C., Li, S.-C., Zhang, Q. S., Xue, Y. G., and Zhong, S. H. (2009). Study of application of complex signal analysis to predicting karst-fractured ground water with GPR. Rock and Soil Mechanics, Vol. 30, Issue 7, pp. 2191–2196. DOI: 10.1016/S1874-8651(10)60073-7.
Liu, X., Sang, Y., and Su, Y. (2012). Detection technology of tunnel leakage disaster based on digital image processing. Chinese Journal of Rock Mechanics and Engineering, Vol. 31, Issue S2, pp. 3779–3786.
Ma, X., Duan, P., and Li, J. (2022). Water leakage detection technology for tunnel lining of Shuozhou-Huanghua Railway based on infrared thermal imaging. Railway Engineering, Vol. 62, Issue 8, pp. 126–129. DOI: 10.3969/j.issn.1003-1995.2022.08.28.
Montero, R., Victores, J. G., Martínez, S., Jardón, A., and Balaguer, C. (2015). Past, present and future of robotic tunnel inspection. Automation in Construction, Vol. 59, pp. 99–112. DOI: 10.1016/j.autcon.2015.02.003.
Musolino, A., Raugi, M., Tucci, M., and Turcu, F. (2007). Feasibility of defect detection in concrete structures via ultrasonic investigation. In: Progress in Electromagnetic Research Symposium, Prague, Czech Republic, August 27–30, 2007, pp. 371–375.
Sandrone, F. and Labiouse, V. (2011). Identification and analysis of Swiss National Road tunnels pathologies. Tunnelling and Underground Space Technology, Vol. 26, Issue 2, pp. 374–390. DOI: 10.1016/j.tust.2010.11.008.
Shi, P. and Li, P. (2015). Mechanism of soft ground tunnel defect generation and functional degradation. Tunnelling and Underground Space Technology, Vol. 50, pp. 334–344. DOI: 10.1016/j.tust.2015.08.002.
State Standard of China (2010). JGJ/T 212-2010. Technical specification for remedial waterproofing of the underground works. Beijing: Standardinform, pp. 79.
State Standard of China (2022). DB32/T 4283-2022. Technical standard for leakage detection of building engineering. Nanjing: Standardinform, pp. 15.
Xu, T., Xu, L., Li, X., and Yao, J. (2018). Detection of water leakage in underground tunnels using corrected intensity data and 3D point cloud of terrestrial laser scanning. IEEE Access, Vol. 6, pp. 32471–32480. DOI: 10.1109/ACCESS.2018.2842797.
Yu, T., Zhu, A., and Chen, Y. (2016). Efficient crack detection method for tunnel lining surface cracks based on infrared images. Journal of Computing in Civil Engineering, Vol. 31, Issue 3, 04016067. DOI: 10.1061/(ASCE)CP.1943-5487.0000645.
Refbacks
- There are currently no refbacks.