ANALYSIS OF COOLING SYSTEM EFFICIENCY
Abstract
Introduction: The main task of cooling systems in the machine room of a data center is to maintain optimal air parameters at the inlet to IT equipment in accordance with the applicable regulatory documents. If the value of air temperature at the inlet to IT equipment exceeds the optimal value, then so-called hot spots occur — the operation of IT equipment in such places can lead to its overheating and failure. The main reason for the occurrence of hot spots is the violation of air circulation between the hot and cold aisles. Purpose of the study: We aimed to analyze the influence of different methods of hot aisle isolation on the efficiency of IT equipment cooling. Methods: We performed modeling of different methods of hot aisle isolation at different capacity values of IT equipment in the STAR-CCM+ program. Result: As a result of studying temperature and air conditions in a data center, we found the most rational way of isolating the hot aisle — top horizontal containments with vertical blind panels in the free rack space.
Keywords
Full Text:
PDFReferences
Abbas, A. M., Huzayyin, A. S., Mouneer, T. A., and Nada, S. A. (2021). Effect of data center servers’ power density on the decision of using in-row cooling or perimeter cooling. Alexandria Engineering Journal, Vol. 60, Issue 4, pp. 3855−3867. DOI: 10.1016/j.aej.2021.02.051.
Almoli, A. M. (2013). Air flow management inside data centres. PhD Thesis in Mechanical Engineering.
ASHRAE (2016). ASHRAE TC9.9 Data Center Power Equipment Thermal Guidelines and Best Practices. [online] Available at: https://www.ashrae.org/File%20Library/Technical%20Resources/Bookstore/ASHRAE_TC0909_Power_White_Paper_22_June_2016_REVISED.pdf [Date accessed September 12, 2022].
Capozzoli, A., Serale, G., Liuzzo, L., and Chinnici, M. (2014). Thermal metrics for data centers: a critical review. Energy Procedia, Vol. 62, pp. 391−400. DOI: 10.1016/j.egypro.2014.12.401.
Cho, J., Park, C., and Choi, W. (2021). Numerical and experimental study of air containment systems in legacy data centers focusing on thermal performance and air leakage. Case Studies in Thermal Engineering, Vol. 26, 101084. DOI: 10.1016/j.csite.2021.101084.
Cho, J. and Woo, J. (2020). Development and experimental study of an independent row-based cooling system for improving thermal performance of a data center. Applied Thermal Engineering, Vol. 169, 114857. DOI: 10.1016/j.applthermaleng.2019.114857.
Herrlin, M. K. (2007). Improved data center energy efficiency and thermal performance by advanced airflow analysis. Digital Power Forum, San Francisco, USA, pp. 10–12.
Huang, Z., Dong, K., Sun, Q., Su, L., and Liu, T. (2017). Numerical simulation and comparative analysis of different airflow distributions in data centers. Procedia Engineering, Vol. 205, pp. 2378-2385. DOI: 10.1016/j.proeng.2017.09.854.
Huawei (2019). E9000 Server V100R001 User Guide. [online] Available at: https://www.manualslib.com/manual/1668286/Huawei-E9000.html [Date accessed September 12, 2022].
Nada, S. A., Said, M. A., and Rady, M. A. (2016). CFD investigations of data centers’ thermal performance for different configurations of CRACs units and aisles separation. Alexandria Engineering Journal, Vol. 55, Issue 2, pp. 959−971. DOI: 10.1016/j.aej.2016.02.025.
Niemann, J., Brown, K., and Avelar, V. (2008). Hot-aisle vs. cold-aisle containment for data centers. White Paper 135. [online] Available at: https://www.missioncriticalmagazine.com/ext/resources/MC/Home/Files/PDFs/WP-APC-Hot_vs_Cold_Aisle.pdf [Date accessed September 12, 2022].
Norouzi-Khangah, B., Mohammadsadeghi-Azad, M. B., Hoseyni, S. M., and Hoseyni, S. M. (2016). Performance assessment of cooling systems in data centers; Methodology and application of a new thermal metric. Case Studies in Thermal Engineering, Vol. 8, pp. 152−163. DOI: 10.1016/j.csite.2016.06.004.
Ponomarev, N. S., Martianova, A. Yu., and Dmitriev, Yu. A. (2021). Assessment of heat gain from server equipment. Bulletin of Civil Engineers, Vol. 2 (85), pp. 166–172. DOI: 10.23968/1999-5571-2021-18-2-166-172.
Priyadumkol, J. and Kittichaikarn, C. (2014). Application of the combined air-conditioning systems for energy conservation in data center. Energy and Buildings, Vol. 68, Part A, pp. 580−586. DOI: 10.1016/j.enbuild.2013.07.082.
Rasmussen, N. (2012). Improving rack cooling performance using airflow management blanking panels. White Paper 44. [online] Available at: https://www.apc.com/us/en/download/document/SPD_SADE-5TPLKQ_EN/ [Date accessed September 12, 2022].
Tatchell-Evans, M., Kapur, N., Summers, J., Thompson, H., and Oldham, D. (2017). An experimental and theoretical investigation of the extent of bypass air within data centres employing aisle containment, and its impact on power consumption. Applied Energy, Vol. 186, Part 3, pp. 457–469. DOI: 10.1016/j.apenergy.2016.03.076.
Timonin, Yu. (2018). Concepts of data center cooling arrangement: in search of maximum efficiency. STA, No. 1. pp. 84–90.
Vertiv (2022). Liebert CRV, Row-based Cooling Unit. [online] Available at: https://www.vertiv.com/ru-emea/products-catalog/thermal-management/in-row-cooling/liebert-crv-row-based-cooling-unit-/ [Date accessed September 12, 2022].
Zhang, M., An, Q., Long, Z., Pan, W., Zhang, H., and Cheng, X. (2017). Optimization of airflow organization for a small-scale date center based on the cold aisle closure. Procedia Engineering, Vol. 205, pp. 1893–1900. DOI: 10.1016/j.proeng.2017.10.279.
DOI: https://doi.org/10.23968/2500-0055-2022-7-4-49-59
Refbacks
- There are currently no refbacks.