RESEARCH ON MECHANICAL PROPERTIES AND GROUTABILITIES OF GROUTED MORTISE-TENON JOINTS FOR PREFABRICATED STRUCTURES

Huang Mingli, Shen Qiaofeng, Zhang Zhancheng

Abstract


Introduction: The paper addresses grouted tenon-and-groove joints in the prefabricated structure of Changchun subway station. For the first time, grouting of prefabricated structure joints with organic epoxy grouting material is analyzed. Purpose of the study: We aimed to make sure that an organic epoxy grouting material can be injected into the joints uniformly and in full and conducted its experimental study. To establish the applicability of the epoxy grouting material in the prefabricated structures, we studied the mechanical properties of the epoxy grout and its adhesive properties in relation to concrete. Methods: In the course of the study, we used a set of test equipment and an independently developed method. Results: High-quality grouting can be guaranteed at an injection pressure of 0.4 MPa and a temperature of 5–10°C. The relationship between the slurry flow rate and time was fit according to the experimental data at 5 and 10°C. The optimal quartz powder ratio was determined at the level of 1:0.6–1:0.8, and the optimal quartz powder particle size (D50) was determined at the level of 18–25 μm. The results of the study can provide references for similar projects in the future.

Keywords


Prefabricated structure, grouted tenon-and-groove joints, epoxy grouting material, groutability, mechanical properties, experiment.

Full Text:

PDF

References


Cao, P., You, M., Liu, G. and Cai, J. (2005). Effect of SiO2 on the strength of epoxy adhesives. China Adhesives, Vol. 14, Issue 4, pp. 15–17.

Ding, P., Tao, L., Yang, X., Zhao, J. and Shi, C. (2018). Three-dimensional dynamic response analysis of a single-ring structure in a prefabricated subway station. Sustainable Cities and Society, Vol. 45, pp. 271–286. DOI: 10.1016/j.scs.2018.11.010.

Du, X.-L., Liu, H.-T. and Xu, C.-S. (2019). Study on seismic performance of beam-column-slab interior joints in cross section of assembled monolithic subway station. Journal of Building Structures, Vol. 40, Issue 8, pp. 51–60.

Li, T.-H. (1995). Design and construction experience of Minsk single arch metro station. Metro and Light Rail, Vol. 2, pp. 44–48.

Li, Z.-P., Li, K.-X., L(u), S.-Q., Su, H.-F. and Wang, C. (2018). Experimental study on stress evolution rule of double tenon-groove joints for prefabricated metro station structure. China Railway Science, Vol. 39, Issue 5, pp. 15–21. DOI: 10.3969/j.issn.1001-4632.2018.05.03.

Li, X.-W. and Liu, Q. (2016). Influencing factor analysis of bending stiffness of single tenon groove joint of subway station constructed with prefabricated element. Railway Standard Design, Vol. 60, Issue 8, pp. 113–117. DOI: 10.13238/j.issn.1004-2954.2016.08.024.

Li, X.-H., Liu, C.-Y. and Zhang, Q. (2019). Comparative analysis of mechanical properties of arched and rectangular subway stations. Construction Technology, Vol. 48, Issue 16, pp. 1–4.

Li, Z.-P., Su, H.-F., Lu, S.-Q., Wang, C., and Xu, X.-Z. (2017). Experimental study on flexural mechanical properties of the double tenon groove joints of prefabricated subway station. China Civil Engineering Journal, Vol. 50, Issue S2, pp. 28–32.

Li, Z.-P., Wang, C., Su, H.-F., Shi, S.-F. (2015a). An experiment study on the evolution law of concrete structure crack and joint seam deformation for tenon groove joints in the prefabricated metro station. China Civil Engineering Journal, Vol. 48, Issue S1, pp. 409–413.

Li, Z.-P., Wang, C., Su, H.-F., Shi, S.-F. and Wang, P. (2015b). Mechanical property of tenon-groove joints for metro station constructed by prefabricated structure. China Railway Science, Vol. 36, Issue 5, pp. 7–11. DOI: 10.3969/j.issn.1001-4632.2015.05.02.

Peng, L.-G. (2004). Study on epoxy resin adhesive for architecture structure. Master’s thesis. Xi’An: Xi’an University of Architecture and Technology.

State Standard of China (1993). GB/T 1041-92. Test method for compressive properties of plastics. Beijing: State Bureau of Quality and Technical Supervision.

Su, H.-F., Li, X.-W. and Wang, C. (2016). Experimental study on flexural capacity of joints of structure of metro station with prefabricated concrete structure. Journal of the China Railway Society, Vol. 38, Issue 9, pp. 118–123. DOI: 10.3969/j.issn.1001-8360.2016.09.017.

Tao, L., Ding, P., Shi, C., Wu, X., Wu, S. and Li, S. (2019). Shaking table test on seismic response characteristics of prefabricated subway station structure. Tunnelling and Underground Space Technology, Vol. 91, 102994. DOI: 10.1016/j.tust.2019.102994.

Vlasov, S. N., Alexandrov, V. N. and Kurakin, N. I. (2002). Essentials of Russian underground railway construction. Beijing: China Railway Press.

Wang, M.-N., Li, Z.-Y. and Wei, L.-H. (2009). Prefabrication technology of tunnel and underground railway. Chengdu: Southwest Jiaotong University Press.

Xu, X.-Z., Li, Z.-P., Zhu, Y.-C. and Su, H.-F. (2017). Study on shear property of tenon groove joint of prefabricated subway station. China Civil Engineering Journal, Vol. 50, Issue S2, pp. 141–146.

Yan, W., Cao, Y.-H. and Li, G.-R. (2004). Development of assembly-type RC structure and building industrialization. Journal of Chongqing Jianzhu University, Vol. 26, Issue 5, pp. 131–136.

Yang, X.-R. and Huang, M.-Q. (2018). Research strategies on new prefabricated technology of underground subway station. Urban Rapid Rail Transit, Vol. 31, Issue 1, pp. 78–85.

Yang, X.-R., Huang, M.-Q. and Lin, F. (2019a). Research strategies on new prefabricated technology for underground metro stations. Urban Rail Transit, Vol. 5, Issue 3, pp. 145–154. DOI: 10.1007/s40864-019-0106-z.

Yang, X.-R., Huang, M.-Q., Lin, F., Wang, C. and Su, H.-F. (2019b). Experimental method of grouted mortise-tenon joint for prefabricated metro station structure. Urban Rapid Rail Transit, Vol. 32, Issue 5, pp. 83–90.

Yang, X.-R., Huang, M.-Q. and Lin, F. (2020a). Research on bending resistance characteristics of grouted mortise-tenon joints for prefabricated metro station structures. China Civil Engineering Journal, Vol. 53, Issue 2, pp. 33–40.

Yang, X.-R., Lin, F. and Huang, M.-Q. (2020b). Experimental research on flexural rigidity of grouted single mortise-tenon joints for prefabricated metro station structures. China Civil Engineering Journal, Vol. 53, Issue 3, pp. 38–43.

Yang, X.-N., Lu, S.-L. and Ge, J.-L. (1997). Bolt-grouting support and its application in weak rock roadway. Chinese Journal of Rock Mechanics and Engineering, Vol. 16, Issue 2, pp. 171–177.

Yang, X.-R., Shi, Z.-H. and Lin, F. (2019c). Influence of geometrical parameters on performance of grouted mortise and tenon joints for application in prefabricated underground structures. Advances in Civil Engineering, Vol. 2019, 3747982. DOI: 10.1155/2019/3747982.

You, M., Cao, P., Wei, X.-H. and Yu, H.-Z. (2006). Effect of SiO2 filler on the elastic modulus and Poisson’s ratio of epoxy layer. China Adhesives, Vol. 15, Issue 3, pp. 12–14.

Yurkevich, P. (1995). Developments in segmental concrete linings for subway tunnels in Belarus. Tunnelling and Underground Space Technology, Vol. 10, No. 3, pp. 353–365. DOI: 10.1016/0886-7798(95)00015-Q.

Zhao, S.-Q. and Yun, H.-M. (1999). Study on rigid particle toughened epoxy resin. China Plastics, Vol. 13, Issue 9, pp. 35–39.

Zhou, S., Zhang, X., Dong, J.-L., Li, S.-L. and Wang, Q.-B. (2017). Grouting technology of prefabricated groove for prefabricated metro station. Building Technique Development, Vol. 44, Issue 18, pp. 70–71.




DOI: https://doi.org/10.23968/2500-0055-2022-7-1-23-32

Refbacks

  • There are currently no refbacks.




     

ISSN: 2500-0055